Model | No.214 | No.214-ISO |
---|---|---|
Glass Column | Inner φ75 + 3 mm, H450 ± 5 mm | Inner φ95 mm, H450 mm, Upper Seal φ40mm |
Flow Meter | Oxygen: Max. 8.6 L/min (Scale 0.1 L/min) Flow Meter: Max. 11 L/min (Scale 0.1 L/min) |
Oxygen: Max. 20 L/min (Scale 0.1 L/min) Flow Meter: Max. 20 L/min (Scale 0.1 L/min) |
Pressure Gauge | Oxygen: Max. 0.1 MPa (Scale 0.002 MPa) Nitrogen: Max. 0.1 MPa (Scale 0.002 MPa) Mixed Gas: Max. 0.1 MPa (Scale 0.002 MPa) |
Oxygen: Max. 0.1 MPa (Scale 0.002 MPa) Nitrogen: Max. 0.1 MPa (Scale 0.002 MPa) Mixed Gas: Max. 0.1 MPa (Scale 0.002 MPa) |
Burner | Flame L6 to 25 mm (Adjustable) | Flame L6 to 25 mm (Adjustable) |
Specimen | Plastic, Rubber and Textile | Plastic, Rubber and Textile |
Accessories | U-shape Specimen Holder, Glass Bead | U-shape Specimen Holder |
Option | Thermometer, Jig for Hoist Specimen, HighTemperature Testing Spec (HT),Oxygen Density Analyzer | Thermometer, Jig for Hoist Specimen, HighTemperature Testing Spec (HT),Oxygen Density Analyzer |
Power Source | ― | AC 100 V, 1-Phase, 5 A, 50/60 Hz |
Heat Source | Mehane Gas (Purity: 98 % Over ) or Urban Gas | Mehane Gas (Purity: 98 % Over ) or Urban Gas |
Gas Supply | Oxygen and Nitrogen | Oxygen and Nitrogen |
Dimensions/ Weight (Approx.) | W600 × D290 × H660 mm, 30 kg | W600 × D250 × H560 mm, 20 kg |
This tester is used to evaluate the burn-resistance of plastic according to the vertical flaming test (VB) and horizontal flaming test (HB). The tester has been improved so that the operator can conduct the test easily by using the jog dial type controller and the touch panel display also equipped with voice guidance. With these functions, the operator can concentrate in watching the condition of the test specimen while controlling the burner to adjust the distance between the flame and the test specimen. Adding the option jigs, the tester will enable to carry out other test methods (5V, VTM, HBF, HF).
Model | No.252-UL-94 (MANUAL) | No.252-UL-94 (ELECTRIC SYSTEM) |
---|---|---|
Chamber | 1,000 × 555 × 900 mm(Volume Approx. 0.5 m3) | 1,000 × 555 × 900 mm(Volume Approx. 0.5 m3) |
Specimen | L125 ± 5 mm, W13.0 ± 0.5 mm, T13 mm or less | L125 ± 5 mm, W13.0 ± 0.5 mm, T13 mm or less |
Burner | L100 ± 10 mm, Inner Diameter φ9.5 ± 0.3 mm | L100 ± 10 mm, Inner Diameter φ9.5 ± 0.3 mm |
Burner Base | Slide type (With Operation Handle), Inclination Angle 45 ± 2°, 20 ± 5° (5 V) | Slide type (With Jog Dial type Controller), Inclination Angle 45 ± 2°, 20 ± 5° (5 V) |
Burner Calibration Device | Flow Meter: Max.150 ml/min (Scale 2 ml/min) (Standard 105 ml/min) Flow Meter: Max. 1,000 ml/min (Scale 10 ml/min) (Standard 965 ml/min) Manometer: Max. 200 (± 100) mmH2O (Scale 1 mmH2O) (Standard 10 mmH2O) Timer, Built-In Thermometer |
Flow Meter: Max.150 ml/min (Scale 2 ml/min) (Standard 105 ml/min) Flow Meter: Max. 1,000 ml/min (Scale 10 ml/min) (Standard 965 ml/min) Manometer: Max. 200 (± 100) mmH2O (Scale 1 mmH2O) (Standard 10 mmH2O) Timer, Built-In Thermometer |
Accessories | Flame Gauge (20 mm) (Option: 125 mm & 38 mm), Ring Stand,Wire Mesh, Dry Cotton Pad, Fireproof Gloves, Gas Lighter | Flame Gauge (20 mm) (Option: 125 mm & 38 mm), Ring Stand,Wire Mesh, Dry Cotton Pad, Fireproof Gloves, Gas Lighter |
Option | Horizontal Burning Support Fixture (HB),Plaque Support Fixture (5 V), Spring Clamp (VTM), Foam Support Fixture | Horizontal Burning Support Fixture (HB),Plaque Support Fixture (5 V), Spring Clamp (VTM), Foam Support Fixture |
Power Source | AC 100 V, 1-Phase, 15 A, 50/60 Hz | AC 100 V, 1-Phase, 10 A, 50/60 Hz |
Heat Source | Methane Gas (Purity: 98 % Over) | Methane Gas (Purity: 98 % Over) |
Dimensions/ Weight (Approx.) | W1,510 × D610 × H1,100 mm 200 kg | W1,500 × D615 × H1,100 mm 230 kg |
This tester is to evaluate the flammability resistance of electric wires by conducting a vertical flammability test. The operator is to fix the test specimen to the upper and lower Chuck and tilt the burner 20° to burn the test specimen for 15 seconds.
Chamber | 1.6 × 1.6 × 1.6 m (Volume Approx. 4 m3) |
---|---|
Specimen | L450 ± 10 mm |
Burner | L100 ± 10 mm, Inner Diameter φ9.5 ± 0.3 mm |
Burner Base | Inclination Angle 20° |
Burner Calibration Device | Flow Meter: Max. 1,000 ml/min (Scale 10 ml/min) (Standard 965 ml/min) Manometer: Max. 400 (± 200) mmH2O (Scale 1 mmH2O) (Standard 125 ± 15 mmH2O) Timer, Thermometer, Slug |
Accessories | Gas Lighter, Flame Gauge, Ring Stand, Gauge for Slug, Dry Cotton Pad |
Power Source | Tester Body: AC 100 V, 1-Phase, 3 A, 50/60 Hz Calibration Device: AC 100 V, 1-Phase, 3 A, 50/60 Hz |
Heat Source | Methane Gas (Purity: 98 % Over) |
Dimensions/ Weight (Approx.) | W1,700 × D1,700 × H2,500 mm, 380 kg (Chamber) |
This tester is used to test the flammability (flaming speed) of thin cloth (scarfs and clothes). The C Method is to measure the speed that the test specimen burned. The operator is to measure the length and the width of the burn and acquire the average to calculate the flammability.
Specimen | 50 × 150 mm |
---|---|
Burner | Propane Gas Burner, Flame Height 16 mm |
Timer | Max. 999.9 sec (Preset type) |
Flame Angle | 45° |
Flaming Time | 1 sec |
Flame Height Adjustment | Needle Valve type, U-Shaped Manometer |
Specimen Holder Angle | 30°、45°、60° |
Power Source | AC 100 V, 1-Phase, 5 A, 50/60 Hz |
Heating Source | Liquid Nitrogen Gas Type 2 No.4 |
機体寸法・Dimensions/ Weight (Approx.) | W400 × D320 × H530 mm, 30 kg |
This tester is used to evaluate the flammability of inner material for cars, tractors, and machines. Attaching the test specimen to a U-shaped specimen holder and flaming the free end for 15 seconds, the operator is to measure the flaming speed of the test
Model | No.440-S1 (FMVSS, ASTM) | No.440-S1(FMVSS、ASTM) |
---|---|---|
Standard | FMVSS | ASTM |
Specimen(Standard) | W 102 mm, L 356 mm, T 13 mm or Less |
W 100 mm, L 300 mm, T 13 mm or Less |
Bunsen Burner | Inner φ10 mm | Inner φ9.5±0.3 mm |
Heat Source | Natural Gas | Methane Gas or Natural Gas (Calorific Value37 ± 1 MJ/m3) |
Specimen Holder | U-shape with Groove (Pitch 25 mm),Marked Line | U-shape with Groove (Pitch 25 mm),Marked Line |
Heat-Resisting Wire | φ0.25 mm | φ0.25 mm |
Accessories | Specimen Attachment Set, Gas Lighter, Termometer, LPG Gas Hose,Hose Band, Flame Gauge, Heat-Resisting Wire,Specimen Holder (Only No.440-S1), Bobbin (Only No.440-S1), Saucer (Only No.440-S2) | Specimen Attachment Set, Gas Lighter, Termometer, LPG Gas Hose,Hose Band, Flame Gauge, Heat-Resisting Wire,Specimen Holder (Only No.440-S1), Bobbin (Only No.440-S1), Saucer (Only No.440-S2) |
Option | Timer (Flaming Time Control), Spirit Level, Heat-Resisting Wire(Spare) | Timer (Flaming Time Control), Spirit Level, Heat-Resisting Wire(Spare) |
Power Source | AC 100 V, 1-Phase, 5 A, 50/60 Hz (with Timer) | AC 100 V, 1-Phase, 5 A, 50/60 Hz (with Timer) |
Dimensions/ Weight (Approx.) | W480 × D250 × H580 mm/ 18 kg | W480 × D250 × H580 mm/ 22 kg |
Model | No.440-S2(JIS、ISO、JASO) | No.440-S2(JIS、ISO、JASO) |
---|---|---|
Standard | JIS、ISO | JASO |
Specimen(Standard) | When W3 to 60mm L 356 mm, T 13 mm or Less When W60 to 100mm L 138 mm, T 13 mm or Less |
W 100 mm, T 356 mm |
Bunsen Burner | Inner φ9.5±0.5 mm | Inner φ10 mm |
Heat Source | Natural Gas (Calorific Value38 MJ/m3) |
Natural Gas (Calorific Value38 MJ/m3) |
Specimen Holder | U-shape with Groove (Pitch 25 mm),Pin Tray | U-shape with Groove (Pitch 25 mm),Pin Tray |
Heat-Resisting Wire | φ0.25 mm | φ0.25 mm |
Accessories | Specimen Attachment Set, Gas Lighter, Termometer, LPG Gas Hose, Hose Band, Flame Gauge, Heat-Resisting Wire, Specimen Holder (Only No.440-S1), Bobbin (Only No.440-S1), Saucer (Only No.440-S2) |
Specimen Attachment Set, Gas Lighter, Termometer, LPG Gas Hose, Hose Band, Flame Gauge, Heat-Resisting Wire, Specimen Holder (Only No.440-S1), Bobbin (Only No.440-S1), Saucer (Only No.440-S2) |
Option | Timer (Flaming Time Control), Spirit Level, Heat-Resisting Wire(Spare) | Timer (Flaming Time Control), Spirit Level, Heat-Resisting Wire(Spare) |
Power Source | AC 100 V, 1-Phase, 5 A, 50/60 Hz (with Timer) | AC 100 V, 1-Phase, 5 A, 50/60 Hz (with Timer) |
Dimensions/ Weight (Approx.) | W480 × D250 × H580 mm/ 22 kg | W480 × D250 × H580 mm/ 22 kg |
This tester is used to test the flammability of textile products (bedclothes). The A-4 method (vertical method) is to measure the burning length and the alternative method (vertical burner method) is to measure the degree of spread of the burn and the after-flame.
Test Method | A-4 Method (Vertical Method) | Alternative Method (Vertical Burner Method) |
---|---|---|
Burning Box | Inner Diameter:W329 × D329 × H762 mm | Inner Diameter:W304.8 × D304.8 × H762 mm |
Specimen | 89 × 254 mm | 70 × 300 mm |
Burner Angle | Busen Burner, Inner Diameter φ11 mm, Flame Height 38 mm, Attaching 25° to Vertical Direction |
Busen Burner, Inner Diameter φ9.5 mm, Flame Height 38 mm, Attaching Vertical |
Burner Movement | Automatic Sliding | Automatic Sliding |
Timer | Ignition Timer: Max. 999.9 sec (Preset method) Flaming Timer: Max. 99,999.9 sec (Preset method) After-flame Timer: Max. 99,999.9 sec (Running method) After-glow Timer: Max. 99,999.9 sec (Running method) |
Ignition Timer: Max. 999.9 sec (Preset method) Flaming Timer: Max. 99,999.9 sec (Preset method) After-flame Timer: Max. 99,999.9 sec (Running method) After-glow Timer: Max. 99,999.9 sec (Running method) |
Igniter | Automatic Ignition (Plug Method) | Automatic Ignition (Plug Method) |
Load | 0.54 N, 1.12 N, 2.23 N, 3.34 N (1 pc Each) | 1.11 N, 2.23 N, 3.33 N, 4.45 N (1 pc Each) |
Accessories | Specimen Holder, Flame Height Measuring Stand, Scale | Specimen Holder, Flame Height Measuring Stand, Scale |
Power Source | AC 100 V, 1-Phase, 5 A, 50/60 Hz | AC 100 V, 1-Phase, 5 A, 50/60 Hz |
Heat Source | Methane Gas (Purity: 97 % Over) | Liquid Petroleum Gas or City Gas |
Dimensions/ Weight (Approx.) | W590 × D330 × H930 mm, 55 kg | W590 × D330 × H930 mm, 55 kg |
This tester is to used to test the flammability of textile products (curtains). The A-1 (45° micro burner method) and A-2 (45° Meckel burner method) methods are to measure the degree of spread of the burn and the after-flame. The D method is to measure the times it takes for the test specimen to completely burn out. The tester can also be organized so that it can conduct the B method which is to measure the after-flame time and flaming distance.
Test Method | Standard Spec | B Method Spec (Surface Flaming Test) |
---|---|---|
Specimen | A-1 and A-2 Method: 350 × 250 mm D Method: W100 mm, Mass 1 g Attaching Angle: 45° |
220 × 400 mm |
Burner | A-1 and D Method: Micro Burner, Flame Height 45 mm A-2 Method: Meckel Burner, Flame Height 65 mm |
Air Mix Burner: Flame Height 24 mm *Pressure of 3.92 kPa/hr |
Timer | ― | Heating Timer: Max. 999.9 sec Flaming: Max. 999.9 sec After-flame Timer: Max. 99999.9 sec After-glow Timer: Max. 99999.9 sec |
Igniter | Automatic Ignition (Plug Method) | Automatic Ignition (Plug Method) |
Accessories | Specimen Holder (A-1 and A-2 Method), Specimen Holding Coil (D Method), Flame Height Measuring Stand, Remote Control Button |
Pearlite Plate, Specimen Holder |
Power Source | AC 100 V, 1-Phase, 3 A, 50/60 Hz | AC 100 V, 1-Phase, 3 A, 50/60 Hz |
Heat Source | Liquid Nitrogen Gas Type 2 No.4 | Liquid Nitrogen Gas Type 2 No.4 |
Dimensions/ Weight (Approx.) | Tester Body: W420 × D330 × H940 mm, 22 kg Control Box: W370 × D300 × H220 mm, 9 kg |
Tester Body: W560 × D330 × H940 mm, 25 kg Control Box: W370 × D300 × H220 mm, 9 kg |